5000 LPH Industrial RO Plant

Commercial/Industrial RO Plants are best suitable for normal drinking application to the specific usage, such as – Food Processing, Pharmaceuticals, Dialysis, Boiler Feeding, Beverages Effluent and Wastewater Purification, Fruit Syrup Production, Hydrogen Production and various other Commercial/Industrial usages

Category:

Product Description

5000 lph TECHNICAL SPECIFICATIONS

 

Flow Rate :

Feed Water                 :             9000 Liter Per Hour

Treated Water             :             6000 Liter Per Hour

Reject Water               :             3000 Liter Per Hour

1 RAW WATER PUMP

Purpose To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter.

Specifications a) MOC : CI

  b) Type : Horizontal Centrifugal

  c) Flow Rate  : 14400 liters per hour

  d) Head : 25 m

  e) Power Required: 3 HP

  f) Electrical : 440 V, Three phase , 50 hz

  g) Cycle : 2900 rpm

  h) Make : Kirlosker, CRI, Crompton Greaves.

  i) Quantity  : 1 No.

 

2 DUAL MEDIA FILTER

Purpose To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes

Specifications Vessel :

 
a) Make : ADS Or Equilent

b) Material of Construction : FRP

c) Diameter : 30”

  d) Height : 72” mm

  e) Testing Pressure : 10 kg/cm2

  f) Opening : Top and Bottom

  g) Quantity : 1 No.

  Valve :

  a) Make : Initiative

  b) Material of Construction :

  c) Type : Multiport Single lever value

  d) Size : 1.5”  inches

  e) Maximum Flow Rate: 24000 LPH

  f) Working Pressure : 2-4 Bar

  g) Working  :  Down-Flow

  Media :

   Mixed bed sand media consisting of the following

  i) Gravel   ii) Pebbles  iii) Quartz Sand  iv) Anthracite

  Average Porosity  50 micron particulate size

  Bed depth  : 600 mm

  Pipelines & Accessories:

   Pipe of PVC 10 Bar tested pressure

 

3 ACTIVTED CARBON FILTER

Purpose To remove the total color, smell, odor, from the water.

Specifications Vessel:

 
a) Make: ADS Or Equilent

b) Material of Construction: FRP

c) Diameter: 30”

  d) Height: 72” mm

  e) Testing Pressure: 10 kg/cm2

  f) Opening: Top & Bottom

  g) Quantity: 1 No.

  Valve:

  a) Make: Initiative

  b) Material of Construction: Noryl

  c) Type: Multiport Single lever value

  d) Size: 1.5 inches

  e) Maximum Flow Rate: 24000 LPH

  f) Working Pressure: 2-4 Bar

  g) Working:  Down-Flow

  Media:

   Mixed bed sand media consisting of the following

  i) Gravel   ii) Pebbles  iii) Carbon

  Average Porosity 50 micron particulate size

  Bed depth: 600 mm

  Pipelines & Accessories:

  Pipe of PVC 10 Bar tested pressure

4
 

DOSING SYSTEM

Purpose To dose Antiscalant chemical to protect the scaling formation on RO membranes.

Specifications a) MOC : PP ( Edose)

  b) Capacity : 6 LPH

  c) Pressure : 7 Bar

  d) Qty. : 1 No.

 

 

5 MICRON FILTER

Purpose To remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level.

Specifications Cartridge Filter & Housing

  Housing  :

  a) Make: Flowtec

  b) MOC of Housing: PP

  c) Length : 20”

  d) Diameter: 5.5”

  e) Quantity : 4 no.

  Cartridge :

  f) Make : Flowtec

  g) Cartridge MOC : Polypropylene

  h) Length:  20”

  i)  Diameter : 4.0”

  j) Quantity: 4 no.

  k) Micron rating : 05 micron

 

6 HIGH PRESSURE PUMP

Purpose To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.

Specifications a) MOC : Stainless Steel

  b) Type : Vertical Multistage

  c) Flow Rate  : 10500 liters per hour

  d) Head : 120 mwc

  e) Power Required : 5 HP

  f) Electrical : 440 V, three phase , 50 hz

  g) Cycle : 2900 rpm

  h) Make CRI or Lubi

7 RO MEMBRANE

Purpose To remove the major part of TDS upto 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery.

Specifications a) Type : Spiral Wounded

  b) Diameter of Membrane : 8.0 inch

  c) Length of Membranes : 1 Mt.

  d) No. of Membranes : 5

  e) Recovery per Membrane : 10-15%

  f) Salt Rejection per Membrane  :  98-99%

  g) Make of Membranes :  Toray or Equilent

  h) System Recovery : 45 -55 %

 

8 RO PRESSURE TUBE

Purpose To pack Reverse Osmosis Membranes and operate at high pressure up to 300 psi

Specifications a) MOC : FRP Composite

  b) Diameter of Pressure Vessel : 8.2 inch

  c) Length of Pressure Vessel :  120”

  d) No. Pressure Vessels : 2

  e) No. of Membrane per Vessel :   2 and 3

  f) Make : Seaflo, Shark or Equilent

  g) Position : Horizontal, Series

  h) Arrays  : 2 No.

 

 

 

9 ELECTRICAL PANAL

Purpose A control panel is provided as a safety measure for the pumps & other electrical items.

Specifications a) Complete Starters, Overload relays, and single-phase preventor for Pump.

  b) Voltmeter, Ammeter, MCB’s, indicating lights

  c) Push Buttons

 

 

10 INSTRUMENTATION

Purpose a) Flow Meter : To measure the online flow of water

  b) Low Pressure Switch  : To protect RO pump from dry running

  c) High Pressure Switch  : To protect RO pump from back pressure

  d)  Pressure Gauges  :  For calculate ^P for each unit in RO system

Specifications Rota Meter :

  Quantity   :   2 Nos.( permeate & reject line)

  Range  : 1.0 cu.m. per hour

  Make  :   Flowtec

  Pressure Switch :

  Quantity   :   2 No.(Low & High)

  Range  : 0-450 psi

  Make  :  Indfos, India

  Pressure Gauges  :

  Quantity  :  6 No.

  Range :  0 – 7 bar

  Dail Size  :  6  inches

  Type  :  Bourdon

  Make  : Seaflo

 